Manufacturer |
KYORITSU |
Meter type |
digital multimeter |
Type of display used |
LCD (6000) |
Sampling |
2,5x/s |
DC voltage measuring range |
0,1m...600m/6/60/600V |
DC voltage measuring accuracy |
±(0,5% + 2 digits) |
AC voltage measuring range |
0,1m...6/60/600V |
AC voltage measuring accuracy |
±(1% + 3 digits) |
DC current measuring range |
0,1µ...600µ/6000µ/60m/600m/6/10A |
DC current measuring accuracy |
±(1,2% + 3 digits) |
AC current measuring range |
0,1µ...600µ/6000µ/60m/600m/6/10A |
AC current measuring accuracy |
±(1,5% + 4 digits) |
Resistance measuring range |
0,1...600/6k/60k/600k/6M/60MΩ |
Resistance measuring accuracy |
±(1% + 2 digits) |
Capacitance measuring range |
10p...40n/400n/4µ/40µ/400µ/4000µF |
Capacitance measuring accuracy |
±(3,5% + 10 digits) |
Frequency measuring range |
0,001...1/10/100/1k/10k/100k/1M/10MHz |
Frequency measuring accuracy |
±(0,1% + 5 digits) |
Temperature measuring range |
-50...300°C |
Duty cycle factor |
0.1...99.9% |
Diode test |
0,4mA, 2,8V |
Continuity test |
acoustic signal for R<100Ω |
Overall dimensions (W x D x H) |
82 x 50 x 161mm |
Weight |
280g |
Power supply |
2 batteries 1,5V LR6 (AA) |