Manufacturer |
AXIOMET |
Meter type |
digital multimeter |
Type of display used |
LCD (6600), with a backlit |
Sampling |
3x/s |
DC voltage measuring range |
0,1m...660m/6,6/66/660/1000V |
DC voltage measuring accuracy |
±(0.8% + 5 digits) |
AC voltage measuring range |
0,1m...660m/6,6/66/660/1000V |
AC voltage measuring accuracy |
±(1% + 5 digits) |
DC current measuring range |
0,1µ...660µ/6600µ/66m/600m/10A |
DC current measuring accuracy |
±(1,5% + 3 digits) |
AC current measuring range |
0,1µ...660µ/6600µ/66m/600m/10A |
AC current measuring accuracy |
±(1,8% + 8 digits) |
True effective value measurement |
True RMS |
Resistance measuring range |
0,1...660/6.6k/66k/660k/6.6M/66MΩ |
Resistance measuring accuracy |
±(1,2% + 2 digits) |
Capacitance measuring range |
1p...6.6n/66n/660n/6.6µ/66µ/660µ/6.6m/66mF |
Capacitance measuring accuracy |
±(3% + 3 digits) |
Frequency measuring range |
0,01...66/660/6,6k/66k/660k/6,6M/66MHz |
Frequency measuring accuracy |
±(0,1% + 3 digits) |
Temperature measuring range |
-55...1000°C |
Temperature measurement accuracy |
±(2% + 3°C) |
Duty cycle factor |
1...99% |
Duty cycle factor measurement accuracy |
±(2% + 10 digits) |
Diode test |
1mA, 2,8V |
Continuity test |
acoustic signal for R<30Ω |
Operating temperature |
0...40°C |
Pollution degree |
2 |
Storage temperature |
-10...60°C |
Overall dimensions (W x D x H) |
90 x 40 x 190mm |
Weight with battery |
500g |
Power supply |
1 battery 9V 6F22, battery not included |
Interface |
USB |
Conform to the norm |
EN61010 1000V CAT III, EN61010 600V CAT IV |
Output connector type |
USB A plug |