Manufacturer |
EXTECH |
Meter type |
AC/DC digital clamp meter |
Max. diameter of measured cable |
43mm |
Type of display used |
LCD (4000), with a backlit |
Sampling |
2x/s |
DC current measuring range |
400/1000A |
DC current measuring accuracy |
±(2,5% + 5 digits) |
AC current measuring range |
400/1000A |
AC current measuring accuracy |
±(2,5% + 8 digits) |
DC voltage measuring range |
400m/4/40/400/1000V |
DC voltage measuring accuracy |
±(1,5% +2 digits) |
AC voltage measuring range |
400m/4/40/400/1000V |
AC voltage measuring accuracy |
±(1,5% + 5 digits) |
True effective value measurement |
True RMS |
Resistance measuring range |
400/4k/40k/400k/4M/40MΩ |
Resistance measuring accuracy |
±(1,5% + 2 digits) |
Capacitance measuring range |
4n/40n/400n/4µ/40µ/400µ/4m/40mF |
Capacitance measuring accuracy |
±(3% + 5 digits) |
Frequency measuring range |
4kHz |
Frequency measuring accuracy |
±(1,5% + 2 digits) |
Temperature measuring range |
-20...760°C |
Non-contact temperature measuring range |
-50...270°C |
Non-contact temperature measuring accuracy |
±(2% or 2˚C) |
Optical resolution |
8:1 |
Continuity test |
acoustic signal for R<40Ω |
Diode test |
0,3mA, 3V |
Dimensions |
270 x 110 x 50mm |
Power supply |
1 battery 9V 6F22 |
Conform to the norm |
EN61010 600V CAT III |
Manufacturer series |
EX800 |