Manufacturer |
AXIOMET |
Meter type |
multimeter calibrator |
Type of display used |
LCD (3999), with a backlit |
DC voltage measuring range |
0,01m...40m/400m/4/40/400V |
DC voltage measuring accuracy |
±(0,2% + 4 digits) |
AC voltage measuring range |
0,01m...400m/4/40/400V |
AC voltage measuring accuracy |
±(0,5% + 4 digits) |
DC current measuring range |
0,01m...40m/400mA |
DC current measuring accuracy |
±(0,2% + 4 digits) |
AC current measuring range |
0,01m...40m/400mA |
AC current measuring accuracy |
±(0,5% + 4 digits) |
Resistance measuring range |
0,1...400/4k/40k/400k/4M/40MΩ |
Resistance measuring accuracy |
±(0,2% + 4 digits) |
Voltage source |
-0,5...5,5V |
Current source |
4μ...20mA |
Frequency measuring range |
0,01...50/500/5k/50k/100kHz |
Frequency measuring accuracy |
±(0,1% + 3 digits) |
Temperature measuring range (with K-type thermocouple) |
-200...1370°C |
Temperature measuring range (with J-type thermocouple) |
-200...700°C |
Temperature measuring range (with R-type thermocouple) |
-40...1760°C |
Temperature measuring range (with S-type thermocouple) |
-20...1760°C |
Temperature measuring range (with T-type thermocouple) |
-200...400°C |
Temperature measuring range (with E-type thermocouple) |
-200...500°C |
Temperature measuring range with N-type thermocouple |
-200...1300°C |
Diode test |
0,2mA, 1V |
Continuity test |
acoustic signal for R<50Ω |
Dimensions |
205 x 95 x 42mm |
Weight |
500g |
Power supply |
4 batteries 1,5V LR03 (AAA), battery not included |
Conform to the norm |
EN61010 600V CAT II |