Clamp for DC-AC AX-203 AXIOMET

Manufacturer AXIOMET
Meter type AC/DC digital clamp meter
Max. diameter of measured cable 23mm
Type of display used LCD 3,75 digit (3999), with a backlit
Sampling 2x/s
DC current measuring range 0,01...40/400A
DC current measuring accuracy ±(2,5% + 6 digits)
AC current measuring range 0,01...40/400A
Bandwidth for AC current measurements 50Hz...400Hz
AC current measuring accuracy ±(3% + 10 digits)
DC voltage measuring range 0,1m...400m/4/40/400/600V
DC voltage measuring accuracy ±(1,5% + 3 digits)
AC voltage measuring range 0,1m...400m/4/40/400/600V
AC voltage measuring accuracy ±(2% + 5 digits)
Bandwidth for AC voltage measurements 50Hz...400Hz
Resistance measuring range 0,1...400/4k/40k/400k/4M/40MΩ
Resistance measuring accuracy ±(1% + 4 digits)
Capacitance measuring range 0,1n...40n/400n/4µ/40µ/100µF
Capacitance measuring accuracy ±(3% + 5 digits)
Frequency measuring range 0,001...5/50/500/5k/50k/150kHz
Frequency measuring accuracy ±(1,2% + 2 digits)
Temperature measuring range -50...760°C
Temperature measurement accuracy ±(3% + 5 digits)
Duty cycle factor 0.5...99%
Duty cycle factor measurement accuracy ±(1,2% + 2 digits)
Continuity test acoustic signal for R<150Ω
Diode test 0,3mA, 1,5V
Dimensions 200 x 50 x 35mm
Weight without batteries 183g
Power supply 1 battery 9V, battery not included
Conform to the norm EN61010 600V CAT III
  • automatic power-off
  • HOLD function
  • REL function
  • display zeroing function in DCA measurements
  • measures temperature, frequency, capcitance and waveform duty cycle
  • 0,01A current measuring reslution
  • diode and continuity test with buzzer
  • overflow indicator
  • contactless voltage detector
  • selection of Celsius or Fahrenheit units
  • low battery indicator
  • case
  • test leads
  • drop-like K-type temperature probe
  • Gross weight: 0.54 kg
  • Collective package: 1 pcs
  • Guarantee (months): 12
Dimensions: 200 x 50 x 35mm
Conform to the norm: EN61010 600V CAT III
Max. diameter of measured cable: 23mm
Meter type: AC/DC digital clamp meter
DC current measuring range: 0,01...40/400A
AC current measuring range: 0,01...40/400A
Capacitance measuring range: 0,1n...40n/400n/4µ/40µ/100µF
Frequency measuring range: 0,001...5/50/500/5k/50k/150kHz
Temperature measuring range: -50...760°C
Weight without batteries: 183g
Sampling: 2x/s
Duty cycle factor: 0.5...99%