Clamp for DC-AC AX-203 AXIOMET
-
AX-203
AX-203
Manufacturer | AXIOMET |
Meter type | AC/DC digital clamp meter |
Max. diameter of measured cable | 23mm |
Type of display used | LCD 3,75 digit (3999), with a backlit |
Sampling | 2x/s |
DC current measuring range | 0,01...40/400A |
DC current measuring accuracy | ±(2,5% + 6 digits) |
AC current measuring range | 0,01...40/400A |
Bandwidth for AC current measurements | 50Hz...400Hz |
AC current measuring accuracy | ±(3% + 10 digits) |
DC voltage measuring range | 0,1m...400m/4/40/400/600V |
DC voltage measuring accuracy | ±(1,5% + 3 digits) |
AC voltage measuring range | 0,1m...400m/4/40/400/600V |
AC voltage measuring accuracy | ±(2% + 5 digits) |
Bandwidth for AC voltage measurements | 50Hz...400Hz |
Resistance measuring range | 0,1...400/4k/40k/400k/4M/40MΩ |
Resistance measuring accuracy | ±(1% + 4 digits) |
Capacitance measuring range | 0,1n...40n/400n/4µ/40µ/100µF |
Capacitance measuring accuracy | ±(3% + 5 digits) |
Frequency measuring range | 0,001...5/50/500/5k/50k/150kHz |
Frequency measuring accuracy | ±(1,2% + 2 digits) |
Temperature measuring range | -50...760°C |
Temperature measurement accuracy | ±(3% + 5 digits) |
Duty cycle factor | 0.5...99% |
Duty cycle factor measurement accuracy | ±(1,2% + 2 digits) |
Continuity test | acoustic signal for R<150Ω |
Diode test | 0,3mA, 1,5V |
Dimensions | 200 x 50 x 35mm |
Weight without batteries | 183g |
Power supply | 1 battery 9V, battery not included |
Conform to the norm | EN61010 600V CAT III |
- automatic power-off
- HOLD function
- REL function
- display zeroing function in DCA measurements
- measures temperature, frequency, capcitance and waveform duty cycle
- 0,01A current measuring reslution
- diode and continuity test with buzzer
- overflow indicator
- contactless voltage detector
- selection of Celsius or Fahrenheit units
- low battery indicator
- case
- test leads
- drop-like K-type temperature probe
- Gross weight: 0.54 kg
- Collective package: 1 pcs
- Guarantee (months): 12
Dimensions: | 200 x 50 x 35mm |
Conform to the norm: | EN61010 600V CAT III |
Max. diameter of measured cable: | 23mm |
Meter type: | AC/DC digital clamp meter |
DC current measuring range: | 0,01...40/400A |
AC current measuring range: | 0,01...40/400A |
Capacitance measuring range: | 0,1n...40n/400n/4µ/40µ/100µF |
Frequency measuring range: | 0,001...5/50/500/5k/50k/150kHz |
Temperature measuring range: | -50...760°C |
Weight without batteries: | 183g |
Sampling: | 2x/s |
Duty cycle factor: | 0.5...99% |
- Extended manual language cz(file pdf, 239.16 Kb)
- Extended manual language de(file pdf, 287.12 Kb)
- Extended manual language en(file pdf, 278.6 Kb)
- Extended manual language hu(file pdf, 285.51 Kb)
- Extended manual language pl(file pdf, 289.54 Kb)
- Extended manual language ro(file pdf, 260.98 Kb)
- Extended manual language sk(file pdf, 255.53 Kb)
-
$10,0000
-
$1,0000
-
$5,0000
-
$1,0000
-
$1000,0000
-
$0,1348