Meters and AC Clamp Probes BM155 BRYMEN

Manufacturer BRYMEN
Meter type power clamp meter
Max. diameter of measured cable 45mm
Type of display used LCD (4000) for current measurement, LCD (6000) for voltage measurement, LCD (9999) for other measurements, with a backlit
Sampling 1x/s (kW, kVA, kVAR), 4x/s
AC current measuring range 0,01...40/400/1000A
AC current measuring accuracy ±(1% + 5 digits) (50/60Hz), ±(2% + 5 digits) (45Hz...500Hz), ±(2,5% + 5 digits) (500Hz...3,1kHz)
Bandwidth for AC current measurements 40Hz...500Hz
DC voltage measuring range 0,1...600V
DC voltage measuring accuracy ±(0,5% + 5 digits)
AC voltage measuring range 0,1...600V
AC voltage measuring accuracy ±(0,5% + 5 digits) (50/60Hz), ±(1,5% + 5 digits) (45Hz...500Hz), ±(2,5% + 5 digits) (500Hz...3,1kHz)
True effective value measurement True RMS AC
Bandwidth for AC voltage measurements 40Hz...500Hz
Resistance measuring range 0,1...999,9Ω
Resistance measuring accuracy ±(1% + 6 digits)
Frequency measuring range 0,01...5/500Hz
Frequency measuring accuracy ±(0,5% + 4 digits)
Temperature measuring range -50...300°C
Temperature measurement accuracy ±(2% + 3°C)
Active power measurement 0...600kW
Active power measuring accuracy ±(4,5% + 6 digits)
Reactive power measurement 0...600kVAR
Reactive power measuring accuracy ±(4,5% + 6 digits)
Apparent power measurement 0...600kVA
Apparent power measuring accuracy ±(3,5% + 6 digits)
Harmonic content measurement 0...99,99%
Harmonic content measuring accuracy ±(1% + 6 digits) (for fundamental harmonic), ±(2% + 6 digits) (for 4...51 harmonic), ±(5% + 6 digits) (for 2 and 3 harmonic)
Continuity test acoustic signal for 10Ω
Pollution degree 2
Dimensions 224 x 78 x 40mm
Weight with battery 224g
Power supply 2 batteries 1,5V LR03 (AAA)
Conform to the norm EN61010 600V CAT III
  • autoranging
  • automatic power-off
  • automatically selects AAC, VAC, VDC measurement on the basis of measured signal
  • HOLD function
  • PEAK HOLD function for AC measurements
  • measures active, reactive and apparent power and power factor
  • continuity test with buzzer
  • THD%-F immediately evaluates harmonic content in measured voltage and current signals
  • batteries
  • soft cover
  • test leads
  • drop-like K-type temperature probe
  • Gross weight: 0.52 kg
  • Guarantee (months): 12
Max. diameter of measured cable: 45mm
Type of display used: LCD (4000) for current measurement, LCD (6000) for voltage measurement, LCD (9999) for other measurements
AC current measuring range: 0,01...40/400/1000A
Frequency measuring range: 0,01...5/500Hz
Weight with battery: 224g
Sampling: 1x/s (kW, kVA, kVAR), 4x/s
Viewed products
TP-15
8.7000
BM195
0.8700
LMC7101BIM5X/NOPB
0.4217
TS3PN
0.8700
FP300
0.8700
LQW18AN6N2D00D
0.0975
JE-1
0.8700
GBU6J
0.5090
S12H
0.8700
VFS15-4007PL-W
0.8700
HP-20
4.3500
E/UK
0.8700
CA301
0.8700
VFS15S-2002PL-W
0.8700
G265C
0.8700