Insulation Resistance Meters UT512 UNI-T
Manufacturer |
UNI-T |
Meter type |
insulation resistance meter |
Type of display used |
LCD (9999) 19mm |
Bargraph |
29 segm. |
Test voltage |
1000VDC (for 2M...10GΩ range), 1500VDC (for range 5M...20GΩ), 2500VDC (for range 10M...100GΩ), 500VDC (for range 0.5M...5GΩ) |
Insulation resistance measuring ranges |
0,1M...500k/100M/5G/10G/20G/100GΩ |
Insulation resistance measuring accuracy |
±(3% + 5 digits) |
AC voltage measuring range |
1...30/600V |
AC voltage measuring accuracy |
±(2% + 5 digits) |
DC voltage measuring range |
1...30/600V |
DC voltage measuring accuracy |
±(2% + 5 digits) |
Continuity test |
acoustic signal for R<30Ω |
Pollution degree |
2 |
Body dimensions |
202 x 155 x 94mm |
Weight with battery |
2kg |
Power supply |
8 batteries 1,5V LR14 |
Conform to the norm |
EN61010 600V CAT III |
- 4 methods of insulation resistance measurement: continuous, during determined time, polarization index and comparative measurement
- autoranging
- automatic power-off
- USB interface
- 18 measurements memory
- continuity test with buzzer
- overload protection
- low battery indicator
- crocodile clips
- test leads
- plastic case
- Gross weight: 3.89 kg
- Guarantee (months):
12
Conform to the norm:
|
EN61010 600V CAT III
|
Meter type:
|
insulation resistance meter
|
Type of display used:
|
LCD (9999) 19mm
|
AC voltage measuring range:
|
1...30/600V
|
Test voltage:
|
1000VDC (for 2M...10GΩ range),
250VDC (for 0,5M...1,99GΩ range),
500VDC (for 1M...3,99GΩ range),
1500VDC (for range 5M...20GΩ),
2500VDC (for range 10M...100GΩ),
500VDC (for range 0.5M...5GΩ)
|
Insulation resistance measuring ranges:
|
0,1M...500k/100M/5G/10G/20G/100GΩ
|